Skip to Content

Steinmann Pins with Trocar Point and Round End Ø 3.2 mm - Pack of 10 Units

(0 review)
Bajo pedido

Buy Skeletal Traction Pin 3.2 mm with Trocar Point

Implant 3.2 mm in diameter indicated for stable, load-bearing fracture fixation and intraoperative reduction of fragments in long bone. Implant steel 1.4441, with a chemically passive, non-magnetic surface, suitable for patients of any age.

Available in 80, 120 and 230 millimetres under a single diameter reference: the department covers everything from fixation in short bone to fixation in the femur or tibia without multiplying stock references. The 3.2 mm gauge provides the rigidity that long bone under load demands, where a thinner pin would flex.

Supplied non-sterile, so the centre can process it in its own autoclave cycle alongside the rest of the instruments. It is a single-use device: it is not reprocessed once implanted.

ApplicationsSkeletal fixation and osteosynthesis
Point typeThree-facet trocar
EndRound
Diameter3.2 mm
Available lengths80 mm, 120 mm and 230 mm
MaterialImplant steel 1.4441 (DIN EN ISO 5832-1)
UseSingle use
PackagingNon-sterile: sterilise before use
SterilisationAutoclave with fractionated pre-vacuum, 134 °C, 5 minutes
RegulationMedical device, class IIb implantable
PresentationPack of 10 units
REF: IU-CSTR1/1508-32

50.98 € 50.98 EUR 61.69 €

61.69 € con impuestos

50.98 €

  • Length
Terms and Conditions
30-day money-back guarantee
Shipping: 2-3 Business Days

Buy Skeletal Traction Pin 3.2 mm with Trocar Point

Implant 3.2 mm in diameter indicated for stable, load-bearing fracture fixation and intraoperative reduction of fragments in long bone. Implant steel 1.4441, with a chemically passive, non-magnetic surface, suitable for patients of any age.

Available in 80, 120 and 230 millimetres under a single diameter reference: the department covers everything from fixation in short bone to fixation in the femur or tibia without multiplying stock references. The 3.2 mm gauge provides the rigidity that long bone under load demands, where a thinner pin would flex.

Supplied non-sterile, so the centre can process it in its own autoclave cycle alongside the rest of the instruments. It is a single-use device: it is not reprocessed once implanted.

ApplicationsSkeletal fixation and osteosynthesis
Point typeThree-facet trocar
EndRound
Diameter3.2 mm
Available lengths80 mm, 120 mm and 230 mm
MaterialImplant steel 1.4441 (DIN EN ISO 5832-1)
UseSingle use
PackagingNon-sterile: sterilise before use
SterilisationAutoclave with fractionated pre-vacuum, 134 °C, 5 minutes
RegulationMedical device, class IIb implantable
PresentationPack of 10 units

Specifications

Length 80 mm, 120 mm, 230 mm
WhatsApp Pregúntanos