Buy Skeletal Traction Pin 4 mm with Trocar Point

Implant 4 mm in diameter indicated for stable, load-bearing fracture fixation and for temporary intraoperative fixation and reduction of fragments. Implant steel 1.4441, chemically passive and non-magnetic on the surface, suitable for patients of any age.

Four millimetres is the reference thickness in adult long bone: below it the pin loses rigidity when the fixation has to bear load; above it, bone stock is removed that is not always needed. Seventeen lengths, from 80 to 310 millimetres, let the size be matched to the bone without changing gauge.

Supplied non-sterile, so the hospital can process it in its own autoclave cycle along with the rest of the instrument set. It is a single-use device: it is not reprocessed once implanted.

ApplicationsOsteosynthesis and temporary fixation of bone fragments
Point typeThree-facet trocar
EndRound
Diameter4 mm
Lengths availableFrom 80 to 310 mm, seventeen sizes
MaterialImplant steel 1.4441 (DIN EN ISO 5832-1)
UseSingle use
PackagingNon-sterile: sterilise before use
SterilisationFractionated pre-vacuum autoclave, 134 °C, 5 minutes
RegulationMedical device, class IIb implantable
PresentationPack of 10 units
REF: IU-CSTR25/1515-40

87.38 € 87.38 EUR 105.73 €

105.73 con impuestos

87.38 €

  • Length
Terms and Conditions
30-day money-back guarantee
Shipping: 2-3 Business Days

Buy Skeletal Traction Pin 4 mm with Trocar Point

Implant 4 mm in diameter indicated for stable, load-bearing fracture fixation and for temporary intraoperative fixation and reduction of fragments. Implant steel 1.4441, chemically passive and non-magnetic on the surface, suitable for patients of any age.

Four millimetres is the reference thickness in adult long bone: below it the pin loses rigidity when the fixation has to bear load; above it, bone stock is removed that is not always needed. Seventeen lengths, from 80 to 310 millimetres, let the size be matched to the bone without changing gauge.

Supplied non-sterile, so the hospital can process it in its own autoclave cycle along with the rest of the instrument set. It is a single-use device: it is not reprocessed once implanted.

ApplicationsOsteosynthesis and temporary fixation of bone fragments
Point typeThree-facet trocar
EndRound
Diameter4 mm
Lengths availableFrom 80 to 310 mm, seventeen sizes
MaterialImplant steel 1.4441 (DIN EN ISO 5832-1)
UseSingle use
PackagingNon-sterile: sterilise before use
SterilisationFractionated pre-vacuum autoclave, 134 °C, 5 minutes
RegulationMedical device, class IIb implantable
PresentationPack of 10 units

Specifications

Length 150 mm, 300 mm, 80 mm, 100 mm, 120 mm, 140 mm, 160 mm, 170 mm, 180 mm, 200 mm, 220 mm, 230 mm, 240 mm, 250 mm, 260 mm, 280 mm, 310 mm