Buy Osteosynthesis Wire 3.2 mm with Double Trocar Point

Implant 3.2 mm in diameter with a trocar point at both ends, indicated for reduction and fixation of metaphyseal fractures, stable load-bearing fracture fixation and temporary intraoperative fixation and reduction of fragments. Implant steel 1.4441, chemically passive and non-magnetic on the surface.

Three point two is the ceiling of this family and, at the same time, the drilling diameter for the 4.5 millimetre cortical screw. That coincidence is not accidental: the wire leaves the path made to the exact size the screw needs. Twenty-six lengths, from 50 to 310 millimetres.

Supplied non-sterile, so the hospital can process it in its own autoclave cycle along with the rest of the instrument set. It is a single-use device: it is not reprocessed once implanted.

ApplicationsOsteosynthesis and temporary fixation of bone fragments
Point typeDouble trocar, one at each end
EndSecond point, no blunt end
Diameter3.2 mm
Lengths availableFrom 50 mm to 310 mm, 26 sizes
MaterialImplant steel 1.4441 (DIN EN ISO 5832-1)
UseSingle use
PackagingNon-sterile: sterilise before use
SterilisationFractionated pre-vacuum autoclave, 134 °C, 5 minutes
RegulationMedical device, class IIb implantable
PresentationPack of 10 units
REF: IU-AKDT543/1159-32

52.12 € 52.12 EUR 63.07 €

63.07 con impuestos

52.12 €

  • Length
Terms and Conditions
30-day money-back guarantee
Shipping: 2-3 Business Days

Buy Osteosynthesis Wire 3.2 mm with Double Trocar Point

Implant 3.2 mm in diameter with a trocar point at both ends, indicated for reduction and fixation of metaphyseal fractures, stable load-bearing fracture fixation and temporary intraoperative fixation and reduction of fragments. Implant steel 1.4441, chemically passive and non-magnetic on the surface.

Three point two is the ceiling of this family and, at the same time, the drilling diameter for the 4.5 millimetre cortical screw. That coincidence is not accidental: the wire leaves the path made to the exact size the screw needs. Twenty-six lengths, from 50 to 310 millimetres.

Supplied non-sterile, so the hospital can process it in its own autoclave cycle along with the rest of the instrument set. It is a single-use device: it is not reprocessed once implanted.

ApplicationsOsteosynthesis and temporary fixation of bone fragments
Point typeDouble trocar, one at each end
EndSecond point, no blunt end
Diameter3.2 mm
Lengths availableFrom 50 mm to 310 mm, 26 sizes
MaterialImplant steel 1.4441 (DIN EN ISO 5832-1)
UseSingle use
PackagingNon-sterile: sterilise before use
SterilisationFractionated pre-vacuum autoclave, 134 °C, 5 minutes
RegulationMedical device, class IIb implantable
PresentationPack of 10 units

Specifications

Length 150 mm, 300 mm, 60 mm, 50 mm, 70 mm, 80 mm, 100 mm, 120 mm, 125 mm, 130 mm, 140 mm, 160 mm, 170 mm, 180 mm, 190 mm, 200 mm, 210 mm, 220 mm, 230 mm, 240 mm, 250 mm, 260 mm, 270 mm, 280 mm, 290 mm, 310 mm