Buy Osteosynthesis Wire 400 mm × 4 mm with Trocar Point and Flat End

Implant 400 mm long and 4 mm in diameter with a trocar point and flat end, indicated for reduction and fixation of metaphyseal fractures, stable, load-bearing fracture fixation and temporary intraoperative fixation and reduction of fragments. Implant steel 1.4441, chemically passive and non-magnetic on the surface.

Four millimetres and forty centimetres in a single piece is the far end of the catalogue. At this gauge the flat end is no longer bent in the field: it is prepared beforehand, with the technique already decided. Whoever orders this reference knows exactly what construct they are building.

Supplied non-sterile, so the hospital can process it in its own autoclave cycle along with the rest of the instrument set. It is a single-use device: it is not reprocessed once implanted.

ApplicationsOsteosynthesis and temporary fixation of bone fragments
Point typeThree-facet trocar
EndFlat
Dimensions400 mm long × 4 mm in diameter
MaterialImplant steel 1.4441 (DIN EN ISO 5832-1)
UseSingle use
PackagingNon-sterile: sterilise before use
SterilisationFractionated pre-vacuum autoclave, 134 °C, 5 minutes
RegulationMedical device, class IIb implantable
PresentationPack of 10 units
REF: IU-AKTP572/1400-40

117.10 € 117.1 EUR 141.69 €

141.69 con impuestos

117.10 €

Terms and Conditions
30-day money-back guarantee
Shipping: 2-3 Business Days

Buy Osteosynthesis Wire 400 mm × 4 mm with Trocar Point and Flat End

Implant 400 mm long and 4 mm in diameter with a trocar point and flat end, indicated for reduction and fixation of metaphyseal fractures, stable, load-bearing fracture fixation and temporary intraoperative fixation and reduction of fragments. Implant steel 1.4441, chemically passive and non-magnetic on the surface.

Four millimetres and forty centimetres in a single piece is the far end of the catalogue. At this gauge the flat end is no longer bent in the field: it is prepared beforehand, with the technique already decided. Whoever orders this reference knows exactly what construct they are building.

Supplied non-sterile, so the hospital can process it in its own autoclave cycle along with the rest of the instrument set. It is a single-use device: it is not reprocessed once implanted.

ApplicationsOsteosynthesis and temporary fixation of bone fragments
Point typeThree-facet trocar
EndFlat
Dimensions400 mm long × 4 mm in diameter
MaterialImplant steel 1.4441 (DIN EN ISO 5832-1)
UseSingle use
PackagingNon-sterile: sterilise before use
SterilisationFractionated pre-vacuum autoclave, 134 °C, 5 minutes
RegulationMedical device, class IIb implantable
PresentationPack of 10 units