Skip to Content

Buy Osteosynthesis Wire 80 mm × 2 mm with 8 mm Thread and Trocar Point

Implant 80 mm long and 2 mm in diameter with a 8 mm thread, indicated for reduction and fixation of metaphyseal fractures, stable, load-bearing fracture fixation and temporary intraoperative fixation and reduction of fragments. Implant steel 1.4441, chemically passive and non-magnetic on the surface.

Eighty millimetres of length with two of diameter and eight of thread: it is a short, thick and well-anchored wire, all three at once. That combination answers a specific case — holding firmly a fragment that sits near the surface and will bear load before it fully unites.

Supplied non-sterile, so the hospital can process it in its own autoclave cycle along with the rest of the instrument set. It is a single-use device: it is not reprocessed once implanted.

ApplicationsOsteosynthesis and temporary fixation of bone fragments
Point typeThree-facet trocar
EndRound
Thread8 mm, behind the point
Dimensions80 mm long × 2 mm in diameter
MaterialImplant steel 1.4441 (DIN EN ISO 5832-1)
UseSingle use
PackagingNon-sterile: sterilise before use
SterilisationFractionated pre-vacuum autoclave, 134 °C, 5 minutes
RegulationMedical device, class IIb implantable
PresentationPack of 10 units

Threaded Kirschner Wires 8 mm with Trocar Point and Round End Ø 2 x 80 mm - Pack of 10 Units

(0 review)
Bajo pedido

Buy Osteosynthesis Wire 80 mm × 2 mm with 8 mm Thread and Trocar Point

Implant 80 mm long and 2 mm in diameter with a 8 mm thread, indicated for reduction and fixation of metaphyseal fractures, stable, load-bearing fracture fixation and temporary intraoperative fixation and reduction of fragments. Implant steel 1.4441, chemically passive and non-magnetic on the surface.

Eighty millimetres of length with two of diameter and eight of thread: it is a short, thick and well-anchored wire, all three at once. That combination answers a specific case — holding firmly a fragment that sits near the surface and will bear load before it fully unites.

Supplied non-sterile, so the hospital can process it in its own autoclave cycle along with the rest of the instrument set. It is a single-use device: it is not reprocessed once implanted.

ApplicationsOsteosynthesis and temporary fixation of bone fragments
Point typeThree-facet trocar
EndRound
Thread8 mm, behind the point
Dimensions80 mm long × 2 mm in diameter
MaterialImplant steel 1.4441 (DIN EN ISO 5832-1)
UseSingle use
PackagingNon-sterile: sterilise before use
SterilisationFractionated pre-vacuum autoclave, 134 °C, 5 minutes
RegulationMedical device, class IIb implantable
PresentationPack of 10 units
REF: IU-AKRO208/0805-20-G

94.66 € 94.66 EUR 114.54 €

114.54 con impuestos

94.66 €

Terms and Conditions
30-day money-back guarantee
Shipping: 2-3 Business Days
WhatsApp Pregúntanos