Threaded Kirschner Wires 7 mm with Trocar Point and Round End Ø 1 x 70 mm - Pack of 10 Units

(0 review)
Bajo pedido

Buy Threaded Osteosynthesis Wire 70 mm × 1 mm with Trocar Point

Bone fixation implant, 70 mm long and 1 mm in diameter, indicated for the reduction and fixation of metaphyseal fractures, diaphyseal fractures and dislocations of the bones of the hand and foot, temporary arthrodesis of small joints and temporary intraoperative fixation of fragments. Implant steel 1.4441, with a chemically passive, non-magnetic surface.

The seven-millimetre threaded section behind the point anchors the wire in cancellous bone and stops it backing out during healing, a common cause of reintervention in percutaneous fixation. The three-facet point enters progressively and generates less heat than a flat point, a factor that determines the viability of the bone around the implant.

Supplied non-sterile, so the centre can process it in its own autoclave cycle alongside the rest of the instruments. It is a single-use device: it is not reprocessed once implanted.

ApplicationsOsteosynthesis and temporary fixation of bone fragments
Point typeThree-facet trocar
EndRound
Thread7 mm, behind the point
Dimensions70 mm length × 1 mm diameter
MaterialImplant steel 1.4441 (DIN EN ISO 5832-1)
UseSingle use
PackagingNon-sterile: sterilise before use
SterilisationAutoclave with fractionated pre-vacuum, 134 °C, 5 minutes
RegulationMedical device, class IIb implantable
PresentationPack of 10 units
REF: IU-AKRO206/0717-10

94.66 € 94.66 EUR 114.54 €

114.54 con impuestos

94.66 €

Terms and Conditions
30-day money-back guarantee
Shipping: 2-3 Business Days

Buy Threaded Osteosynthesis Wire 70 mm × 1 mm with Trocar Point

Bone fixation implant, 70 mm long and 1 mm in diameter, indicated for the reduction and fixation of metaphyseal fractures, diaphyseal fractures and dislocations of the bones of the hand and foot, temporary arthrodesis of small joints and temporary intraoperative fixation of fragments. Implant steel 1.4441, with a chemically passive, non-magnetic surface.

The seven-millimetre threaded section behind the point anchors the wire in cancellous bone and stops it backing out during healing, a common cause of reintervention in percutaneous fixation. The three-facet point enters progressively and generates less heat than a flat point, a factor that determines the viability of the bone around the implant.

Supplied non-sterile, so the centre can process it in its own autoclave cycle alongside the rest of the instruments. It is a single-use device: it is not reprocessed once implanted.

ApplicationsOsteosynthesis and temporary fixation of bone fragments
Point typeThree-facet trocar
EndRound
Thread7 mm, behind the point
Dimensions70 mm length × 1 mm diameter
MaterialImplant steel 1.4441 (DIN EN ISO 5832-1)
UseSingle use
PackagingNon-sterile: sterilise before use
SterilisationAutoclave with fractionated pre-vacuum, 134 °C, 5 minutes
RegulationMedical device, class IIb implantable
PresentationPack of 10 units