Skip to Content

Threaded Kirschner Wires 6 mm with Trocar Point and Round End Ø 1.2 x 150 mm - Pack of 10 Units

(0 review)
Bajo pedido

Buy Osteosynthesis Wire 150 mm × 1.2 mm with 6 mm Thread and Trocar Point

Implant 150 mm long and 1.2 mm in diameter with a 6 mm thread, indicated for reduction and fixation of metaphyseal fractures, diaphyseal fractures and dislocations of the bones of the hand and foot and temporary intraoperative fixation and reduction of fragments. Implant steel 1.4441, chemically passive and non-magnetic on the surface.

The difference between five and six millimetres of thread looks trivial until you look at where this wire works: in hand bone the cortex measures tenths of a millimetre. One more millimetre of thread can be the difference between gripping the far cortex or settling for the near one alone.

Supplied non-sterile, so the hospital can process it in its own autoclave cycle along with the rest of the instrument set. It is a single-use device: it is not reprocessed once implanted.

ApplicationsOsteosynthesis and temporary fixation of bone fragments
Point typeThree-facet trocar
EndRound
Thread6 mm, behind the point
Dimensions150 mm long × 1.2 mm in diameter
MaterialImplant steel 1.4441 (DIN EN ISO 5832-1)
UseSingle use
PackagingNon-sterile: sterilise before use
SterilisationFractionated pre-vacuum autoclave, 134 °C, 5 minutes
RegulationMedical device, class IIb implantable
PresentationPack of 10 units
REF: IU-AKRO203/1206-12

113.14 € 113.14 EUR 136.90 €

136.9 con impuestos

113.14 €

Terms and Conditions
30-day money-back guarantee
Shipping: 2-3 Business Days

Buy Osteosynthesis Wire 150 mm × 1.2 mm with 6 mm Thread and Trocar Point

Implant 150 mm long and 1.2 mm in diameter with a 6 mm thread, indicated for reduction and fixation of metaphyseal fractures, diaphyseal fractures and dislocations of the bones of the hand and foot and temporary intraoperative fixation and reduction of fragments. Implant steel 1.4441, chemically passive and non-magnetic on the surface.

The difference between five and six millimetres of thread looks trivial until you look at where this wire works: in hand bone the cortex measures tenths of a millimetre. One more millimetre of thread can be the difference between gripping the far cortex or settling for the near one alone.

Supplied non-sterile, so the hospital can process it in its own autoclave cycle along with the rest of the instrument set. It is a single-use device: it is not reprocessed once implanted.

ApplicationsOsteosynthesis and temporary fixation of bone fragments
Point typeThree-facet trocar
EndRound
Thread6 mm, behind the point
Dimensions150 mm long × 1.2 mm in diameter
MaterialImplant steel 1.4441 (DIN EN ISO 5832-1)
UseSingle use
PackagingNon-sterile: sterilise before use
SterilisationFractionated pre-vacuum autoclave, 134 °C, 5 minutes
RegulationMedical device, class IIb implantable
PresentationPack of 10 units
WhatsApp Pregúntanos