Buy Osteosynthesis Wire 150 mm × 1.1 mm with 10 mm Thread and Trocar Point

Bone fixation implant 150 mm long and 1.1 mm in diameter, indicated for reduction and fixation of metaphyseal fractures, diaphyseal fractures and dislocations of the bones of the hand and foot, and temporary intraoperative fixation of fragments. Implant steel 1.4441, chemically passive and non-magnetic on the surface.

The difference from a round millimetre is one tenth, and it exists for a reason: there are fragments that give way at 1 mm and will not take 1.2. This gauge covers that gap without forcing a choice between a wire that flexes and one that removes too much bone going in.

Supplied non-sterile, so the hospital can process it in its own autoclave cycle along with the rest of the instrument set. It is a single-use device: it is not reprocessed once implanted.

ApplicationsOsteosynthesis and temporary fixation of bone fragments
Point typeThree-facet trocar
EndRound
Thread10 mm, behind the point
Dimensions150 mm long × 1.1 mm in diameter
MaterialImplant steel 1.4441 (DIN EN ISO 5832-1)
UseSingle use
PackagingNon-sterile: sterilise before use
SterilisationFractionated pre-vacuum autoclave, 134 °C, 5 minutes
RegulationMedical device, class IIb implantable
PresentationPack of 10 units

Threaded Kirschner Wires 10 mm with Trocar Point and Round End Ø 1.1 x 150 mm - Pack of 10 Units

(0 review)
Bajo pedido

Buy Osteosynthesis Wire 150 mm × 1.1 mm with 10 mm Thread and Trocar Point

Bone fixation implant 150 mm long and 1.1 mm in diameter, indicated for reduction and fixation of metaphyseal fractures, diaphyseal fractures and dislocations of the bones of the hand and foot, and temporary intraoperative fixation of fragments. Implant steel 1.4441, chemically passive and non-magnetic on the surface.

The difference from a round millimetre is one tenth, and it exists for a reason: there are fragments that give way at 1 mm and will not take 1.2. This gauge covers that gap without forcing a choice between a wire that flexes and one that removes too much bone going in.

Supplied non-sterile, so the hospital can process it in its own autoclave cycle along with the rest of the instrument set. It is a single-use device: it is not reprocessed once implanted.

ApplicationsOsteosynthesis and temporary fixation of bone fragments
Point typeThree-facet trocar
EndRound
Thread10 mm, behind the point
Dimensions150 mm long × 1.1 mm in diameter
MaterialImplant steel 1.4441 (DIN EN ISO 5832-1)
UseSingle use
PackagingNon-sterile: sterilise before use
SterilisationFractionated pre-vacuum autoclave, 134 °C, 5 minutes
RegulationMedical device, class IIb implantable
PresentationPack of 10 units
REF: IU-AKRO2/1208-11

114.34 € 114.34 EUR 138.35 €

138.35 con impuestos

114.34 €

Terms and Conditions