Skip to Content

Kirschner Wires with Double Trocar Point Ø 2.7 x 240 mm - Pack of 10 Units

(0 review)
Bajo pedido

Buy Osteosynthesis Wire 240 mm × 2.7 mm with Double Trocar Point

Implant 240 mm long and 2.7 mm in diameter with a trocar point at both ends, indicated for reduction and fixation of metaphyseal fractures, stable load-bearing fracture fixation and temporary intraoperative fixation and reduction of fragments. Implant steel 1.4441, chemically passive and non-magnetic on the surface.

It is a reference with no variants, and that already says what it is for: some systems are cannulated to exactly 2.7 millimetres and their working length calls for 240. When that is the technique, rounding to 2.5 or 2.8 is not an alternative.

Supplied non-sterile, so the hospital can process it in its own autoclave cycle along with the rest of the instrument set. It is a single-use device: it is not reprocessed once implanted.

ApplicationsOsteosynthesis and temporary fixation of bone fragments
Point typeDouble trocar, one at each end
EndSecond point, no blunt end
Dimensions240 mm long × 2.7 mm in diameter
MaterialImplant steel 1.4441 (DIN EN ISO 5832-1)
UseSingle use
PackagingNon-sterile: sterilise before use
SterilisationFractionated pre-vacuum autoclave, 134 °C, 5 minutes
RegulationMedical device, class IIb implantable
PresentationPack of 10 units
REF: IU-AKDT480/1249-27

50.68 € 50.68 EUR 61.32 €

61.32 € con impuestos

50.68 €

Terms and Conditions
30-day money-back guarantee
Shipping: 2-3 Business Days

Buy Osteosynthesis Wire 240 mm × 2.7 mm with Double Trocar Point

Implant 240 mm long and 2.7 mm in diameter with a trocar point at both ends, indicated for reduction and fixation of metaphyseal fractures, stable load-bearing fracture fixation and temporary intraoperative fixation and reduction of fragments. Implant steel 1.4441, chemically passive and non-magnetic on the surface.

It is a reference with no variants, and that already says what it is for: some systems are cannulated to exactly 2.7 millimetres and their working length calls for 240. When that is the technique, rounding to 2.5 or 2.8 is not an alternative.

Supplied non-sterile, so the hospital can process it in its own autoclave cycle along with the rest of the instrument set. It is a single-use device: it is not reprocessed once implanted.

ApplicationsOsteosynthesis and temporary fixation of bone fragments
Point typeDouble trocar, one at each end
EndSecond point, no blunt end
Dimensions240 mm long × 2.7 mm in diameter
MaterialImplant steel 1.4441 (DIN EN ISO 5832-1)
UseSingle use
PackagingNon-sterile: sterilise before use
SterilisationFractionated pre-vacuum autoclave, 134 °C, 5 minutes
RegulationMedical device, class IIb implantable
PresentationPack of 10 units