Skip to Content

Threaded Kirschner Wires 10 mm with Trocar Point and Round End Ø 2.7 x 160 mm - Pack of 10 Units

(0 review)
Bajo pedido

Buy Osteosynthesis Wire 160 mm × 2.7 mm with 10 mm Thread and Trocar Point

Implant 2.7 mm in diameter indicated for reduction and fixation of metaphyseal fractures, temporary intraoperative fixation and reduction of fragments and stable, load-bearing fracture fixation. Implant steel 1.4441, chemically passive and non-magnetic on the surface.

This is a single reference, with no variants: 2.7 millimetres in diameter and 160 in length. It exists because some fixation systems are cannulated to that exact size, and neither 2.5 nor 2.8 will fit. It is not a general-purpose gauge, it is the part ordered once the technique is already decided.

Supplied non-sterile, so the hospital can process it in its own autoclave cycle along with the rest of the instrument set. It is a single-use device: it is not reprocessed once implanted.

ApplicationsOsteosynthesis and temporary fixation of bone fragments
Point typeThree-facet trocar
EndRound
Thread10 mm, behind the point
Dimensions160 mm long × 2.7 mm in diameter
MaterialImplant steel 1.4441 (DIN EN ISO 5832-1)
UseSingle use
PackagingNon-sterile: sterilise before use
SterilisationFractionated pre-vacuum autoclave, 134 °C, 5 minutes
RegulationMedical device, class IIb implantable
PresentationPack of 10 units
REF: IU-AKRO45/1165-27

118.48 € 118.48 EUR 143.36 €

143.36 con impuestos

118.48 €

Terms and Conditions
30-day money-back guarantee
Shipping: 2-3 Business Days

Buy Osteosynthesis Wire 160 mm × 2.7 mm with 10 mm Thread and Trocar Point

Implant 2.7 mm in diameter indicated for reduction and fixation of metaphyseal fractures, temporary intraoperative fixation and reduction of fragments and stable, load-bearing fracture fixation. Implant steel 1.4441, chemically passive and non-magnetic on the surface.

This is a single reference, with no variants: 2.7 millimetres in diameter and 160 in length. It exists because some fixation systems are cannulated to that exact size, and neither 2.5 nor 2.8 will fit. It is not a general-purpose gauge, it is the part ordered once the technique is already decided.

Supplied non-sterile, so the hospital can process it in its own autoclave cycle along with the rest of the instrument set. It is a single-use device: it is not reprocessed once implanted.

ApplicationsOsteosynthesis and temporary fixation of bone fragments
Point typeThree-facet trocar
EndRound
Thread10 mm, behind the point
Dimensions160 mm long × 2.7 mm in diameter
MaterialImplant steel 1.4441 (DIN EN ISO 5832-1)
UseSingle use
PackagingNon-sterile: sterilise before use
SterilisationFractionated pre-vacuum autoclave, 134 °C, 5 minutes
RegulationMedical device, class IIb implantable
PresentationPack of 10 units
WhatsApp Pregúntanos