Skip to Content

Threaded Kirschner Wires 8 mm with Trocar Point and Round End Ø 1.2 x 70 mm - Pack of 10 Units

(0 review)
Bajo pedido

Buy Osteosynthesis Wire 70 mm × 1.2 mm with 8 mm Thread and Trocar Point

Implant 70 mm long and 1.2 mm in diameter with a 8 mm thread, indicated for reduction and fixation of metaphyseal fractures, diaphyseal fractures and dislocations of the bones of the hand and foot and temporary intraoperative fixation and reduction of fragments. Implant steel 1.4441, chemically passive and non-magnetic on the surface.

The ratio between thread and length is what defines this reference: eight millimetres of grip on a seventy millimetre wire. In short bone there is no run over which to spread the anchorage, so it has to concentrate near the point. It is the answer to small-joint arthrodesis that must hold for weeks.

Supplied non-sterile, so the hospital can process it in its own autoclave cycle along with the rest of the instrument set. It is a single-use device: it is not reprocessed once implanted.

ApplicationsOsteosynthesis and temporary fixation of bone fragments
Point typeThree-facet trocar
EndRound
Thread8 mm, behind the point
Dimensions70 mm long × 1.2 mm in diameter
MaterialImplant steel 1.4441 (DIN EN ISO 5832-1)
UseSingle use
PackagingNon-sterile: sterilise before use
SterilisationFractionated pre-vacuum autoclave, 134 °C, 5 minutes
RegulationMedical device, class IIb implantable
PresentationPack of 10 units
REF: IU-AKRO207/0708-12

94.66 € 94.66 EUR 114.54 €

114.54 con impuestos

94.66 €

Terms and Conditions
30-day money-back guarantee
Shipping: 2-3 Business Days

Buy Osteosynthesis Wire 70 mm × 1.2 mm with 8 mm Thread and Trocar Point

Implant 70 mm long and 1.2 mm in diameter with a 8 mm thread, indicated for reduction and fixation of metaphyseal fractures, diaphyseal fractures and dislocations of the bones of the hand and foot and temporary intraoperative fixation and reduction of fragments. Implant steel 1.4441, chemically passive and non-magnetic on the surface.

The ratio between thread and length is what defines this reference: eight millimetres of grip on a seventy millimetre wire. In short bone there is no run over which to spread the anchorage, so it has to concentrate near the point. It is the answer to small-joint arthrodesis that must hold for weeks.

Supplied non-sterile, so the hospital can process it in its own autoclave cycle along with the rest of the instrument set. It is a single-use device: it is not reprocessed once implanted.

ApplicationsOsteosynthesis and temporary fixation of bone fragments
Point typeThree-facet trocar
EndRound
Thread8 mm, behind the point
Dimensions70 mm long × 1.2 mm in diameter
MaterialImplant steel 1.4441 (DIN EN ISO 5832-1)
UseSingle use
PackagingNon-sterile: sterilise before use
SterilisationFractionated pre-vacuum autoclave, 134 °C, 5 minutes
RegulationMedical device, class IIb implantable
PresentationPack of 10 units
WhatsApp Pregúntanos